ATF2: pour un faisceau stable de 37nm Cécile Rimbault RAPA
ATF2: pour un faisceau stable de 37nm ATF/ATF2 layout Schedule LAL contributions Emittance and coupling corrections studies
Accelerator Test Facility
ATF2 beam line (fin 2008) Accelerator Test Facility
Small nominal beam size Obtain y ~ 37nm Maintain for long time Stabilization of beam center Down to < 2nm by nano-BPM Bunch-to-bunch feedback of ILC-like train Objectifs de ATF2
ATF – beam operation schedule LAL: P. Bambade, J. Brossard, G. Le Meur, Y. Renier, C. Rimbault, F. Touze S. Bai (LAL/IHEP), M. C. Alabau Pons (LAL/IFIC)
Slide from Tauchi
ATF2 activities at LAL M. Alabau, P. Bambade*, S. Baï, J. Brossard, G. Le Meur*, Y. Renier*, C. Rimbault*, F. Touze* Espace de phase dans la ligne d’extraction de ATF(2) (CR, JB, MA, PB): - Evaluation / amélioration des méthodes de mesure de l’emittance verticale en présence d’erreurs. - Identification des sources d’erreur et de couplage. - Tentatives de mesure et de correction du couplage. - Etude des non-linearités dans la section partagée entre le Damping Ring et la ligne d’extraction. Coordination de la tâche dédiée à la correction du couplage xy pour le commissioning ATF2. - Etude de la validité des méthodes de mesure du couplage. - Evaluation de l’optique minimale nécessaire à la correction du couplage. - Automatisation des procedures de mesure et de correction. Pulse to pulse Feedback au point d’interaction dans ATF2 (YR, PB): - Modélisation et analyse des mouvements du sol. - Développement d’un algorithme de feedback des trajectoires. - Modélisation des corrections faisceau et étude de tolérances. - Reconstruction et contrôle de l’orbite, devant permettre la stabilisation du faisceau. - Implémentation dans le programme de monitorage général “Flight Simulator”. Focalisation finale au point d’interaction de ATF2 (SB, YR, PB): - Optimisation du spot avec des tolérances réduites pour le commissioning de ATF2 et differentes positions de l’IP. - Limites and dépendances de la correction de chromaticité dans la section de focalisation finale. - Contrôle des aberrations optiques. Determination de la carte de champs du quadrupôle QM7, partagé entre la ligne d’EXT et le DR(MA, PB, GLM, FT): - Evaluation des non-linearités du champs. - Etude des alternatives à l’utilisation de QM7.
Etudes réalisées sur ATF de nov 2007 à mai 2008 Problématique: L’émittance mesurée dans EXT est 3 fois celle mesurée dans le DR. causes possibles: méthodes de reconstruction Non linéarité de champ magnétique dans les aimants partagés avec le DR Faisceau couplé a l’entrée de EXT...?
La Mesure d’Emittance 5 wire scanners station At each station, 3 wire scanner orientations for beam size measurement. For vertical (or horizontal) projected emittance measurement, only one wire scanner orientation is needed. For x-y coupling measurement a tilt angle is also required. Diagnostic section ( x = y = ) Wire thickness = 10 m & 50 m 90° 10° 0°
La Mesure d’Emittance Coupling terms Measurable terms Matrice de transfert optique Emittance horizontale projetée: Emittance verticale projetée: 11 et 33 mesurés directement 13 mesurés avec wire scanner u (10 o ): Agapov, Blair, Woodley, PRST-AB (2007) P. Emma, M. Woodley, ATF-99-04:
Multi wire-scanner position method Difficulté: Nécessite une bonne avance de phase entre les wire-scanners,qui dépend de l’optique et du faisceau à l’entrée de EXT.
Waist scan method - 1 Transfer Matrix: normal quad: R tot = RQ skew quad: R tot = RQ K Coupling terms Measurable terms The squares of the measured beam sizes, 11 M, 13 M, 33 M, at a wire scanner position can be expressed as a parabolic function of the strength of the scanned quad, described by 3 fit parameters A, B, C: ij =A ij (k-B ij ) 2 +C ij
Waist scan method - 2 With normal quad scan: With skew quad scan:
from raw data corrected from dispersion x = (3.3 +/- 0.4 ) nm.rad Quad scan (QF5X) Quad scan (QF6X) Multi-wire emittance reconstruction based on Monte-Carlo simulation : x = (3.3 +/- 1.3 ) nm.rad ~ 0.66% DR value (?) y = (82 +/- 26 ) pm.rad ~ 300 % DR value Results from 12 march 2008 shift The vertical emittance in the DR was measured : x = 5 nm.rad (?) y = 34 pm.rad y = (114 +/- 13 ) pm.rad
EXT line beta function and phase advance for 3 differents input Twiss parameter set (optics from 12 th march shift) Input from the DR solution : x = m x = y = m y = Input from multi- wire meas. : x =2.5m x =1.0 y = 0.68 m y =1.1 Input from quad scan meas. : x =6.7m x =1.6 y = 0.51 m y =-1.1 The « measure »phase advance between wire scanner is very bad need to match the optics « on-line ».
Comprendre l’augmentation de l’émittance Dans les aimants partagés entre le DR et EXT, le faisceau passe hors axe, où le champ magnetique serait non lineaire couplage du faisceau Mise en évidence du couplage par scan d’un skew quad Reproduire les mesures par simulation (MAD8) en ajoutant une composante multipolaire à QM7. Calculer une correction adaptée via MAD8 minimisation de y par itérations successives des forces skew quad prévus à cet effet. Appliquer la correction calculée (forces des skew minimisant y ) à la machine Refaire les mesures
Comprendre l’augmentation de l’émittance
Difficultés expérimentales Mesures non reproductibles d’un jour à l’autre. Variation de la dispersion à court terme (1 ou 2 heures) Méthodes de mesure de l’émittance couteuses en temps Pour ATF2 nécessité d’automatiser les procédures de corrections (orbit, dispersion, couplage...) et de mesures de l’émittance. Flight Simulator: interface matlab entre le système de control de ATF2 et Lucretia, software de simulation du transport d’un faisceau dans un accélérateur. Permettra le control de la machine.
FS example: Simulation Procedure (100 seeds) apply standard errors (EXT only) steer flat (EXT only) launch into FFS –use FFS feedback measure dispersion in diagnostic section –scan input beam energy –measure orbits –fit position vs energy at each BPM correct dispersion in diagnostic section –back-propagate measured η to start of diagnostic section to get η0 and η′0 –use QF1X + QF6X multiknobs for ηx and η′x –correct η y and η′ y using skew quads in inflector correct coupling –scan 4 skew quadrupoles sequentially –deduce projected ε y from wire scanner measurements –set each skew quad to minimize projected ε y
Standard Error Parameters - wiki
Dispersion Correction Vertical dispersion / dispersion' as measured in EXT diagnostic section before and after dispersion correction. y (mm) ’y’y
Coupling Correction IP coupling terms before and after EXT coupling correction procedure. xy x’y
Simulation Performance IP spot sized considerably reduced. Full simulation including FFS errors and tuning ok- FFS tuning removes remaining errors from EXT tuning.
Full comparison mean value/ std for y & y 1:SE 2:SE+QM7 3:SE+DR 4:SE+DR+QM7 5:SE+DR+2QM7 Before CC CC 2 skew CC 4 skew Etude de l’optique mininale pour la correction du couplage
Conclusions Emittance verticale dans EXT = 3 X DR Sources de couplage dans EXT: QM7 possible mais pas seulement. Nécessité d’automatiser les procédures de mesure et de corrections Flight simulator 4 skew quads reduisent l’emittance de 15% par rapport à 2 Recherche de méthodes plus directes dans la correction du couplage