AMBIANCES THERMIQUES CHAMP D’APPLICATION ANALYSE DES RISQUES ET PREVENTION VALEURS D’ACTION PROGRAMME DE MESURES ORG ET TECH MESURES SI FROID EXCESSIF MESURES SI CHALEUR EXCESSIVE SURVEILLANCE DE SANTE TRAVAILLEURS SENSIBLES INFOS ET FORMATIONS
CHAMP ET DEFINITIONS EMPLOYEURS ET TRAVAILLEURS/ LOI BE COMITE, DELEGATION, TRAVAILLEURS
ANALYSE DES RISQUES, FACTEURS TEMPERATURE DE L’AIR HUMIDITE RELATIVE EN % VITESSE DE L’AIR EN M/SEC RAYONNEMENT THERMIQUE CHARGE PHYSIQUE DE TRAVAIL METHODE DE TRAVAIL ET EQUIPEMENT T VT ET EPI
ANALYSE DES RISQUES FCT EVOLUTION DES FACTEURS -PENDANT LA DUREE DU TRAVAIL -SELON LA SAISON -SELON LES CIRCONSTANCES DE TRAVAIL MESURAGES SI NECESSAIRE
ANALYSE DES RISQUES METHODE D’ANALYSE SELON AVIS SPPTS ACCORD DU COMITE SI DESACCORD, METHODES SPF MESURES DE PREVENTION ADAPTEES FCT DES VALEURS D’ACTION FCT NORMES CONFORT THERMIQUE
VALEURS D’ACTION FROID T° AIR NE PEUT ETRE INFERIEURE A: 18° SI TRAVAIL TRES LEGER 16° SI TRAVAIL LEGER 14° SI TRAVAIL MOYEN 12° SI TRAVAIL LOURD 10° SI TRAVAIL TRES LOURD
VALEURS D’ACTION CHALEUR T°AIR NE PEUT PAS DEPASSER : 29° SI TRAVAIL LEGER OU TRES LEGER 26° SI TRAVAIL MOYEN 22° SI TRAVAIL LOURD 18° SI TRAVAIL TRES LOURD SELON INDICE WBGT FCT HUMIDITE, T° SECHE, VITESSE AIR, RAYONNEMENT
PROGRAMME DE MESURES (1) EN CAS DE DEPASSEMENTS VALEURS PRENDRE DES MESURES TECHNIQUES ET ORGANISATIONNELLES FACTEURS D’AMBIANCE CHARGE DE TRAVAIL METHODES DE TRAVAIL DUREE ET INTENSITE DE L’EXPO
PROGRAMME DE MESURES (2) EN CAS DE DEPASSEMENTS VALEURS PRENDRE DES MESURES TECHNIQUES ET ORGANISATIONNELLES -ADAPTATION DES HORAIRES/PAUSES -EQUIP PROTECTION INDIVIDUELS -BOISSONS
EXEMPLES DE MESURES /CHALEUR
ALTERNANCE TRAVAIL/PAUSES PROTECTION=BONNE, SI APPLICATION 1.NORMES EN ISO NBN 7243/ 7933/ 9886 2.AUTRE ALTERNATIVE SUR AVIS MT 3.AUTRE SUR CONVENTION COLLECTIVE DE TRAVAIL, DE PROTECTION EQUIVALENTE A 1er POINT 4.MESURES DANS L’ANNEXE 1 5.DYNAMIQUES
ALTERNANCE TRAVAIL REPOS ANNEXE 1 (article 6) WBGT TR LEGER TR MILOURD TR LOURD TR TRES LOURD 45’TRAVAIL/15’REPOS 29,5° 27° 23° 19° 30’TRAVAIL/30’REPOS 30° 28° 24,5° 21°
PRESCRIPTIONS MINIMALES FROID 1. FROID TECHNOLOGIQUE (EX FRIGO) - VT ET EPI (EQUIP PROT INDIVIDUEL) - BAISSE VITESSE AIR - SECHAGE VETEMENT DE TRAVAIL(VT) - BOISSONS CHAUDES - PAUSES AU CHAUD
PRESCRIPTIONS MINIMALES FROID 2. FROID CLIMATIQUE (1) DU 1/11 AU 31/3, DANS DES LIEUX OUVERTS OU EXTERIEURS (EX CHANTIER) DISPOSITIFS DE CHAUFFAGE PRESENTS SI T°<5°: MISE EN MARCHE PAUSES EN LOCAL CHAUFFE, AVEC ACCORD SYNDICAL
MESURES FROID TRES DECONSEILLE
TRAVAIL AU FROID
PRESCRIPTIONS MINIMALES FROID 2. FROID CLIMATIQUE (2) DU 1/11 AU 31/3, DANS LES COMPTOIRS EXTERIEURS DE COMMERCE DE DETAIL SI T°<5°: INTERDICTION DE TRAVAIL SI 5°<T°<10°, CHAUFFAGE PUISSANT OU PAUSE EN LOCAL CHAUFFE PLANCHER ET TOIT INTERDIT ENTRE 19H ET 8H, >2H SANS PAUSE 1H, >4H/JOUR
COMPTOIRS EXTERIEURS
MESURES PROTECTION CHALEUR ORIGINE TECHNOLOGIQUE (EX FONDERIE) SI DEPASSEMENT DES VALEURS, -AVEC CONVECTION: DISPOSITIFS DE VENTILATION ARTIFICIELLE, ASPIRATION -AVEC RAYONNEMENTS (EX METAL): ECRANS, VT, EPI BAISSE DE LA DUREE D’EXPOSITION PAUSES AU FRAIS (SALLE DE RECUP) BOISSONS FRAICHES/AVIS MT
TRAVAIL AU CHAUD
TRAVAUX AU CHAUD
MESURES CHALEUR 2. ORIGINE CLIMATIQUE(DEHORS ET DEDANS) SI DEPASSEMENT DES VALEURS, - DISPOSITIFS DE VENTILATION MONTES EN 48H BAISSE DE LA DUREE D’EXPO PAUSES AU FRAIS(SALLE RECUP) BOISSONS FRAICHES/AVIS MT ALTERNANCE TRAVAIL/REPOS (ANNEXE 1) SI PERSISTANCE DU PROBLEME
MESURES CHALEUR 3. CHALEUR EXCESSIVE TECHN ET CLIMAT -MEMES MESURES QUE POUR CHALEUR TECHN -PROTECTION CONTRE LE RAYONNEMENT 4. INTERV PROGRAMMEES DE COURTE DUREE A CHALEUR +++ (EX CENTRALE, FOUR,…) AVIS PREALABLE DU MT SUR EXPOSITION SURVEILLANCE DE SANTE INSTANTANEE POSSIBLE
AMBIANCES DE TRAVAIL TRANSPORT
SURVEILLANCE DE SANTE 1.TRAV EXPOSES REGULIERMENT, TECHNOLOGIQUEMENT AU FROID: T°<8° - CHALEUR: >VALEURS ACTION 2.TRAV PRESTANT A L’EXTERIEUR SURVEILLANCE PREALABLE ET ANNUELLE
TRAVAIL AU CHAUD
CHARGE DE TRAVAIL
CHANTIER AU CHAUD
SENSIBILITES PARTICULIERES - MATERNITE,JEUNES, VIEUX - MALADIES COMME HYPO ET HYPERTHYROIDIE, MAIGREUR, OBESITE, PROBLEMES DE STABILISATION DE T°, DE TA, PROBLEMES CIRCULATOIRES (VARICES, RAYNAUD..) MESURES SPECIFIQUES SUR AVIS DU MEDECIN DU TRAVAIL
INFO FORMATION ANALYSE RISQUES ET GESTION RISQUES PROBLEMES DE SANTE LIES A L’EXPO VALEURS D’ACTION MESURES DEPISTAGE DES PROBLEMES INFLUENCE DES CARACT INDIVIDUELLES PRATIQUES SURES COND DE SURVEILLANCE DE SANTE
CHARGE PHYSIQUE DE TRAVAIL POUR UN TRAVAIL CONTINU DE 8H (ENERGIE/SEC EN WATTS) TRES LEGERE: <117 WATTS LEGERE: DE 117 A 234 WATTS MOYENNE: DE 235 A 360 WATTS LOURDE: DE 361 A 468 WATTS TRES LOURDE >468 WATTS
ESTIMATIONS TRAVAIL LEGER (180 W): EX. SECRETARIAT TRAVAIL MOYEN (300 W): EX. CONDUITE ENGIN TRAVAIL LOURD (410 W): EX. MANUTENTION TRAVAIL TRES LOURD (520 W) : EX TERRASSEMENT
EFFETS LIES AU FROID HYPOTHERMIE-COMA-MORT ENGELURES FRISSONS ENGOURDISSEMENT des EXTREMITES FROID
EFFETS LIES AU CHAUD SENSATION DE CHALEUR COUP DE CHALEUR CRAMPE DE CHALEUR HYPERTHERMIE DESHYDRATATION DECES
INFORMATIONS TECHNIQUES ISO 7243 DECRIT INDICE WBGT=WET BULB GLOBE THERMOMETER(FICHE 21) ISO 7933 DECRIT LE PREDICTED HEALTH STRAIN A PARTIR DE L’INDICE WBGT ET DE L’HISTOIRE DE L’EXPOSITION=PROGRAMME INFORMATIQUE(FICHE 22)
INFORMATIONS TECHNIQUES NBN EN ISO 9886 ERGONOMIE: EVALUATION DE L’ASTREINTE THERMIQUE PAR DES MESURES PHYSIOLOGIQUES
BIBLIOGRAPHIE BROCHURE : AMBIANCES THERMIQUES (SERIE SOBANE) SITE WEB DU SPF EMPLOI: WWWEMPLOI.BELGIQUE.BE -INFOS -LEGISLATION -BROCHURES
FIN QUESTIONS?