‘Dee’ du TK CMS Modules ‘PS’
Test 1: results M55J fiber, Allcomp K9 C-foam, unpotted groove FNAL dummy module, power 7.5W System pressure 13.1 bar ~ -32°C ΔT (pipe → cooling plate) = 8.2°C ΔT (cooling plate → upper sensor) = 2.9°C ΔT (pipe → upper sensor) = 11.1°C
Test 2: results M55J fiber, Allcomp K9 C-foam, potted groove FNAL dummy module, power 7.5W System pressure 13.3 bar ~ -32°C ΔT (pipe → cooling plate) = 9.2°C ΔT (cooling plate → upper sensor) = 2.5°C ΔT (pipe → upper sensor) = 11.7°C
Test 3: results K13D2U fiber, Allcomp K9 C-foam, unpotted groove FNAL dummy module, power 7.5W System pressure 13.0 bar ~ -32°C ΔT (pipe → cooling plate) = 5.2°C ΔT (cooling plate → upper sensor) = 2.9°C ΔT (pipe → upper sensor) = 8.1°C
Tests prototype 2-secteur TEDD – arbre de décision DEBUT Peaux avec trous Airex épais Pas d’inserts Pas de tuyaux Pas de rebord “Marbre” fibre+verre Problème avec fenêtres des C-foams/trous des inserts Problème couche colle au milieu ou avec rebord OUI OUI Peaux SANS trous Airex épais Pas d’inserts Pas de tuyaux Pas de rebord “Marbre” fibre+fibre Peaux avec trous 2x Airex fin, pas de sillon Pas d’inserts Pas de tuyaux Rebord Fléchi? Fléchi? Fléchi? NON OUI Problème de marbre NON NON Peaux avec trous Airex épais Pas d’inserts Pas de tuyaux Pas de rebord “Marbre” fibre+fibre Peaux avec trous 2x Airex fin, sillon vers la peau Inserts supérieurs longs Pas de tuyaux Rebord Fléchi? NON ??? OUI Peaux SANS trous Stratifié quasi-isotrope Cuisson temp. ambiente Airex épais Pas d’inserts Pas de tuyaux Pas de rebord “Marbre” fibre+fibre OUI Fléchi? Fléchi? NON Contraintes introduites par les tuyaux? OUI NON Contraines introduites dans les peaux par sillon/inserts Besoin stratifié quasi-isotrope et/ou cuisson à temp. ambiente Nick Lumb 12/12/16
1er Test chez Workshape