Inspection panel for Electric back-ups Coaxial exchanger 4,5 turns Refrigareted connection By-pass 8,5 Hydraulic connection
Coaxial Exchanger Polystyrene insulation Condensation sensor Stainless-steel tank
Improvement of the performances – by combining thermo-electric Electric back-ups 3 – 6 kW OPTION 1st flow: thermodynamic 2nd flow: electric
Module hydraulique Composants Controller box Air bleeder Tank 16L + Coaxial Exchanger Safety valve Expansion vessel class A circulating pump Les éléments constituant le module hydraulique… Refrigerated connections Hydraulic connections Manometer Return Flow
Electric box Excellia Regulator card Place for Electric back-ups Place for extension card (2 circuits and/or pool) Hydraulic modul connections DHW Relay (option) Interface card
Hydraulic options Boiler Kit Electric back-ups 2° circuit kit High flow Circulating pump Choix des kit hydraulique: Kit 2 circuits (plancher chauffant + radiateur basse température), attention le circulateur de l’Alféa doit être remplacer par une tuyauterie, Et doit être mis en place dans le coffret. Le coffret peut être raccorder sous le module hydraulique. Le kit comprend un vanne 3 voies pour le plancher, et un circulateur en direct, une sonde de départ permet de gérer les 2 circuits indépendamment. Le kit RLV permet d’adapter l’Alféa sur une installation existante équipé d’une chaudière. Il peut se raccorder sous la PAC et peut recevoir le kit 2 circuits. La bouteille de découplage permet d’adapter le kit RLV sur une chaudière équipé d’un circulateur non démontable. Le kit ECS est une vanne 3 voies directionnelle permettant de basculer en mode sanitaire ou chauffage automatiquement (priorité sanitaire par cycle) 2 choix de ballon 200 ou 300 L avec appoint électrique. Le kit piscine : groupe hydraulique composé d’un échangeur en titane, des vannes et raccord + la régulation auquel il faut ajouter le kit piscine Alféa. Le kit circulateur haut débit permet d’adapter l’alféa sur des installations ayant beaucoup de pertes de charge (400w en vitesse 3) Balancing vessel Swiming pool Kit
Hydraulic accessories Choix des kit hydraulique: Kit 2 circuits (plancher chauffant + radiateur basse température), attention le circulateur de l’Alféa doit être remplacer par une tuyauterie, Et doit être mis en place dans le coffret. Le coffret peut être raccorder sous le module hydraulique. Le kit comprend un vanne 3 voies pour le plancher, et un circulateur en direct, une sonde de départ permet de gérer les 2 circuits indépendamment. Le kit RLV permet d’adapter l’Alféa sur une installation existante équipé d’une chaudière. Il peut se raccorder sous la PAC et peut recevoir le kit 2 circuits. La bouteille de découplage permet d’adapter le kit RLV sur une chaudière équipé d’un circulateur non démontable. Le kit ECS est une vanne 3 voies directionnelle permettant de basculer en mode sanitaire ou chauffage automatiquement (priorité sanitaire par cycle) 2 choix de ballon 200 ou 300 L avec appoint électrique. Le kit piscine : groupe hydraulique composé d’un échangeur en titane, des vannes et raccord + la régulation auquel il faut ajouter le kit piscine Alféa. Le kit circulateur haut débit permet d’adapter l’alféa sur des installations ayant beaucoup de pertes de charge (400w en vitesse 3) DHW tank DS VCM 200, 300L or PECS PAC 300L Kit DHW Swiming pool Kit Swiming pool Kit
Controller accessories Extension card Cooling Kit Room sensor T55 Or wireless T58 La régulation peut être équipé d’une sonde d’ambiance T55. (auto-adaptation possible, influence et correction // de la loi d’eau) Ou de la régulation d’ambiance T75 (déport de la programmation et du paramétrage en ambiance) Il est possible de faire du rafraîchissement via le kit (connectique interface régulation + isolant de pompe) Remote control T75 or wireless T78
Installation
Gaz and liquid pipe (inche) Diametre Liquid (inchs) Extensa Refrigerated connection Gaz and liquid pipe (inche) Ref PAC Diametre Gaz (inchs) Diametre Liquid (inchs) Length mini (metre) Length maxi (metre) S5 1 / 2’’ 1 / 4’’ 5 15/30 S6 S8 5 / 8’’ 3 / 8’’ S10 15/20 Liaison mini 5 m pour S8, 10, 13, 16 Liaison Maxi en fonction de la charge unité extérieure (ex: S5 10 mètres) Liaison Maxi avec ajout de charge (20 m avec 20 g/ m) Dénivelé maxi 15m pour S5, 6, 20m pour S8 et 30m pour S10, 13, 16
Extensa Electric connections DHW electric back-ups 3G 2,5² Interconnexion 4G 1,52 Interconnexion 3G 2,52 Electric back-ups 3G 62 Circuit breaker 32A Circuit breaker D curve 16A et 20A Alféa 5 et 6 3G 1,52 Alféa 8 3G 2,52 Alféa 10
Extensa Electric connections Interconnexion 4G 1,52 Electric back-ups 3G 6² Circuit breaker 32A Circuit breakerr D curve 25A (11) 32 A (14) Alféa 11 3G 42 Alféa 14 3G 62
Adjustable Electric back-ups Electric backup single phase Adjustable Electric back-ups 3 or 6kW Safety thermostat Relay 1° and 2° level Terminal block Automatic air bleeder You have to replace the manual air bleeder by an automatic with the electric back-ups kit => If the heat exchanger is badly drained, risk to release the safety thermostat
Electric back-ups single phase You have to cut insulation before to integrate the automatic air bleeder
Electric back-ups tri-phases 9kW Modulating relay Electric back-ups tri-phases 9kW Safety thermostat Card connection X82
2 floor heating possible 2 circuits Configuration Alfea Circulating pump Kit 2Z Kit 2 zones de chauffage Déplacer le circulateur PAC dans le kit et le remplacer par la tuyauterie. La régulation de la PAC contrôle le kit avec 2 lois d’eau. 2 floor heating possible
2 circuits Configuration Extension Card to manage 2 circuits (Option) Mixing valve Alfea Class A circulating pump Class A circulating pump integrated
Extension card Power Supply Room sensor 2nd zone Circulating pump and 2nd circuit valve or fil pilote connection Modem Contact 2nd circuit flow sensor Swimming pool Directionnal Valve Swimming pool sensor
(hydraulic part) (with compatible insulation cold mode) Extension card Kit (2nd zone) – 075311 2 circuits Kit (hydraulic part) (with compatible insulation cold mode) Swimming pool Kit
Possibilité de faire 2 zones de chauffage Option ECS Possibilité de faire 2 zones de chauffage ECS Kit ECS ou Chauffage Le kit sanitaire comprends une vanne 3 voies directionnelle et une sonde sanitaire. Ce qui permet à la régulation de la PAC de contrôler une priorité sanitaire en fonction de la programmation sanit.
Boiler kit ( integrated option) Boiler option Application : Floor heating radiators Préparation DHW Boiler kit ( integrated option)
Boiler option 1 to 3 circuits – 2 zones possible TA Contact 20° 15° 10° 2° 0° -5° -10° 1 to 3 circuits – 2 zones possible TA Contact Outside sensor A AB Integrated B Lorsque la T°C calculé extérieure est > à P3700 (2°C) le compresseur fonctionne seul. Si la T°c calculé est < à P3700 la régulation enclenche la vanne 3 voies de RLV ainsi que la chaudière. Lorsque la T°C de départ RLV est atteinte la chaudière est arrêtée la vanne reste ouvert 20 minutes (P3705). Attention si la T°C de départ RLV descend en dessous de la consigne chauffage + rapidement que 20 minutes => la vanne reste ouverte. Si la chaudière est équipée d’un ballon P3705 = 0 Le compresseur est arrêté si la T°C de retour PAC est > à 65°C Option or
Boiler option 1 to 3 circuits – 2 zones possible TA Contact 20° 15° 10° 2° 0° -5° -10° 1 to 3 circuits – 2 zones possible TA Contact Outside sensor Ajouter une bouteille de découplage si la chaudière est équipée d’un circulateur non démontable. Integrated Option or
Possibilité de faire 2 zones de chauffage + ECS + piscine Option Piscine Possibilité de faire 2 zones de chauffage + ECS + piscine Echangeur piscine Kit piscine Sonde piscine ou Chauffage Le kit sanitaire comprends une vanne 3 voies directionnelle et une sonde sanitaire. Ce qui permet à la régulation de la PAC de contrôler une priorité sanitaire en fonction de la programmation sanit.
Cooling Option Insulation Insulation Connection Be Careful : Don’t use this kit with boiler and radiator