Télécharger la présentation
La présentation est en train de télécharger. S'il vous plaît, attendez
Publié parkamel Behri Modifié depuis plus de 6 années
1
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-100 RBS On-Site Integration OMT 39H OMT 41H GSM RBS Commissioning
2
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-101 Connection Cable The Same cable for RBS 2000 cabinets, But we add to it a new (Serial RJ cable) with the following pin assignment.
3
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-102
4
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-103 Work Process RBS Integration
5
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-104 Switching On RBSs 1.Switch on the RBS main power, the switch for the RBS main power is located outside the cabinet. 2.Wait unitl all units are powered up before continuing. When the Operational indicator is double-flashing on an RU, it means that the RU is performing change and saving software in internal flash memory. Do not disturb any RU or change any RU to local mode while an RU is indicating a function change. RUs continue to indicate function changes until a function change restart takes place. If indicator on the digital unit is flashing, software need to loaded. NOTE: It can take up to 10 minutes before all units in the cabinet are in operation.
6
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-105 Connecting the OMT Connect the cable to LMT A of the DUG
7
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-106 Creating IDB 1.Start the OMT. 2.In the Configuration menu, click Create IDB (This opens up the Create IDB window). Creating IDB
8
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-107 Creating IDB 3.Click New to open the Define Setup for Cabinet Window. Defining Cabinet Setup
9
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-108 Creating IDB 4.In the Cabinet Type box, select the cabinet type. Defining Cabinet Setup
10
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-109 Creating IDB 5.In the Power System box, select the power system. Defining Cabinet Setup
11
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1010 Creating IDB 6.In the Climate System box, select climate system (if applicable). Defining Cabinet Setup
12
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1011 Creating IDB 7.Click Ok. Defining Cabinet Setup
13
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1012 Creating IDB 8.Click New to open the Antenna Systems for Sector window. Defining Antenna Sector Setup
14
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1013 Creating IDB 9.Click New to open the Antenna Systems for Sector window. Defining Antenna Sector Setup 10.Click New to open the Antenna Systems for Sector window.
15
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1014 Creating IDB Defining Antenna Sector Setup 10.In the Frequency box, select the frequency used. 11.In the TMA box, select one of the following: Yes if TMAs have been installed. No if TMAs have not been installed.
16
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1015 Creating IDB Defining Antenna Sector Setup 12.In the TX combining box, select applicable combining type. In the RX diversity box, select the applicable RX diversity type if applicable. 13.Click Ok in the Define Antenna System window to confirm.
17
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1016 Creating IDB Defining Antenna Sector Setup 14.Click Ok in the Define Antenna System window to confirm.
18
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1017 Creating IDB Defining Antenna Sector Setup 15.Click Ok in the Define Antenna System window to confirm. 16.If addtitional antenna systems will be defined in the sector, then repeat the steps above.
19
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1018 Creating IDB Selecting the Final Configuration 17.In the Final Configuration Selection window, select the site cell configuration (SCC). 18.Verify that correct parameters have been entered. Click Ok.
20
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1019 Creating IDB Selecting the Final Configuration 19.In the OMT dialogue box asking ”Do you want to resue data in the previous configuration?”, click one of the following: Yes – IDB modification only No – configuration of entirely new IDB 20.In the OMT dialogue box asking ”Do you really want to overwrited the IDB data in the OMT?”, click Yes.
21
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1020 Defining Present RU 1.Click the Configuration Menu or click the shortcut button/toolbar as shown to open the Define Present RU window.
22
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1021 Defining Present RU 2.Move the RUs in the configuration used to Present box by selecting the RU to be moved and clicking ← key (or double-clicking the RUs to be moved). 3.Click Ok when finished.
23
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1022 Defining Alarm Inlets ( External Alarms ) ParemeterValid ValuesDefaultDescription Type Closing Breaking ClosingSpecifies how an external device indicates an alarm and must be set to enable correct supervision. A fault is indicated by closing or breaking the sensor loop. ID 0 – 9 A – F 0Uniquely idetifies the external alarm equipment. The value is sent in external alarm reports to the O&M center. Severity Level 1 Level 2 Level 1Indicates the severity of the external alarm. The operator determines the values to be used for the alarms. CommentCharacter string with up to 62 charaters. Valid charaters are: 0..9, A..Z, space ! # $ % & ’ () * + -. / : ; ? _ An empty character string The operator can add a description of the external alarm. The value is sent to the O&M center in external alarm reports. External Alarm Setting
24
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1023 Defining Alarm Inlets ( External Alarms ) 1.On the Configuration menu, click Define and Alarm Inlets to open the Define Alarm Inlets window.
25
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1024 Defining Alarm Inlets ( External Alarms ) 2.In the Hardware unit box, select ”SCU” or ”SAU”.
26
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1025 Defining Alarm Inlets ( External Alarms ) 3.In the Alarm Inlet Information window, select an unused alarm inlet.
27
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1026 Defining Alarm Inlets ( External Alarms ) 4.In the Inlet Usage box, select ”External Alarm”. ARAE = Antenna Related Auxillary Equipment
28
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1027 Defining Alarm Inlets ( External Alarms ) 5.In the Type box, define the alarm type as ”Closing (when there is an alarm, the alarm cable closes) or ”Breaking” (when there is an alarm, the alarm cable breaks).
29
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1028 Defining Alarm Inlets ( External Alarms ) 6.In the ID box, select an alarm inlet number.
30
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1029 Defining Alarm Inlets ( External Alarms ) 7.In the Severity box, set the severity level of the alarm.
31
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1030 Defining Alarm Inlets ( External Alarms ) 8.Add a comment in the Comment box, if required.
32
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1031 Defining Alarm Inlets ( External Alarms ) 9.Click Apply after defining the alarm.
33
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1032 Defining Alarm Inlets ( External Alarms ) 10.Repeat steps 2 to 8 to define the remaining alarms. 11.Click Ok when all alarms have been defined.
34
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1033 Saving IDB 1.On the Configuration menu, click Save IDB.
35
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1034 Installing IDB 1.Physically connect the OMT to the RBS.
36
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1035 Installing IDB 2.Before clicking the ”Install” icon/toolbar, make sure that the DUG is in Local Mode. 3.Either press the button on the DUG or right click on the DUG in the Cabinet View then click Change Local/Remote State. 4.Make sure that the yellow LED is in steady or constant yellow light. 5.Click Install Note: Do not touch the RBS when any indicators are double- flashing.
37
Top right corner for field-mark, customer or partner logotypes. See Best practice for example. Slide title 40 pt Slide subtitle 24 pt Text 24 pt Bullets level 2-5 20 pt 04_03813 LZU 108 8069 Uen, Rev A© Ericsson AB 2010GSM RBS Commissioning2010-06-1036
Présentations similaires
© 2024 SlidePlayer.fr Inc.
All rights reserved.